STAGE EFFECTS
RESOURCES


PYROTECHNICS SAFETY GUIDE:

Material Safety Data Sheet:
Coloured Smoke

 

Pyrotechnic

Coloured Smoke

 

Product Codes

T3020 – T3039

 

Description

The pyrotechnics are constructed from moulded plastic and filled with a smoke composition.

 

Ignition is by an electric fuse (1.3-1.7 ohm).

 

Technical Classification

Proper Shipping Name Articles, pyrotechnic

Hazard Code 1.4S

UN Classification 0432

 

Packaging

All smokes are packed in boxes of 10 to UN specifications.

 

Chemicals

Potassium Chlorate

Lactose

Hydrocarbon Dye

 

Hazard

Potential hazards during normal functioning: Do not fire near combustible materials.

 

Malfunctioning: In the event of a failure to fire, return to manufacturer for disposal.

 

In Storage: This pyrotechnic is electrically fired and, although protected, should be kept away from any high-density electromagnetic radiation (RADHAZ). Store in a cool, dry place.

 

General Instructions

Ensure you have the correct storage facilities with access only being given to a competent person.

 

Do not smoke when handling pyrotechnic.

 

Keep away from naked flame.

 

Use only with a professional firing system with a safety key and momentary button.

 

Do not use in confined spaces.

 

Do not use near flammable materials.

 

Keep pyrotechnics away from source of electrical ignition (e.g. batteries, stray currents, mobile phones etc.).

 

Take care to ensure that the hot particles do not cause injury to persons or damage to items/equipment/floors etc. If in doubt, test outdoors beforehand.

 

Pyrotechnics must only be fired by a person with a direct view of the firing area, ensuring all persons are well clear.